APPLICATION GUIDE

INCISE UltraGuard™ application guide

Clear protection for decorative surfaces

UltraGuard is a solvent-based acrylic protective topcoat for microcement, concrete, terrazzo and timber. Specify matt, satin or gloss. Use indoors or on sheltered exterior surfaces; it is not recommended for permanent water immersion.

Plan the quantity

Allow 8–12 m² per litre per coat, depending on the substrate. A 6 L resin-and-hardener kit covers approximately 48–72 m² in one coat, 24–36 m² in two coats or 16–24 m² in three coats, before waste. Do not count the separate thinner as yield.

Satin finish on a decorative corridor floor
01 / SITE AND SUBSTRATE

Prepare the surface

Check conditions

Apply at 10–30°C. Do not coat a surface affected by rising damp or apply above 80% relative humidity. Protect the work from direct rain for the first 24 hours.

Microcement

Wait until fully cured (minimum 5–7 days). Lightly sand with 180–220 grit to remove imperfections, then vacuum. The surface must be clean, dry and dust-free.

Concrete

Allow new concrete to cure for at least 28 days. Check that moisture is below 4%. Mechanically grind to open the pores; remove laitance, oil, curing compounds and dust.

Terrazzo and timber

Polish terrazzo to the desired level; lightly sand if needed for adhesion. Leave it dry and dust-free. For timber, check moisture is below 12%, sand with 120–180 grit and remove all dust. Prime if the timber type requires it.

Vacuuming dust from sanded microcement
02 / BATCHING

Measure and mix

Set up before opening the kit

Have graduated measures, a clean mixing pail, slow-speed mixer, timer and short-nap or microfibre roller ready. UltraGuard is flammable: provide ventilation, wear protective gloves and eye protection, and keep heat, sparks and flames away. Consult the product SDS before use.

Measure by volume

Pre-stir Component A (resin). Add one part Component B (hardener) to two parts resin. Example: 1 L resin + 0.5 L hardener = 1.5 L mixed coating. The full kit contains 4 L resin and 2 L hardener.

Mix, rest and time the batch

Mix slowly for 2–3 minutes, then let stand for 2–3 minutes. Pot life is 2–3 hours at 23°C. Only mix what the crew can place within that time. The separate 1 L of urethane thinner is not part of the 2:1 ratio. Do not dilute without INCISE technical approval.

Slow-speed mixing of the clear coating
03–04 / APPLICATION

Roll thin coats and recoat

03 / Apply the first coat

Use a short-nap or microfibre roller. Spread a thin, even coat and avoid repeatedly rolling back over it. The datasheet also permits professional airless spray; this illustrated method shows roller application.

04 / Apply the next coat

Touch dry is approximately 3–4 hours. The normal recoating interval is 6–12 hours. Apply at least two coats; three are recommended for high-traffic areas. Keep each coat thin and even.

If the interval is missed

If more than 24 hours have passed, lightly abrade with 220 grit and remove all dust before recoating. For a delay beyond 12 hours but no more than 24 hours, confirm the next step with INCISE; the datasheet gives no separate procedure for this interval.

Applying a thin clear coat with a short-nap roller
05 / HANDOVER

Protect the finish as it cures

Release the area in stages

Count from the final coat. Allow 24 hours before light foot traffic and 5–7 days for full cure. A touch-dry surface is not ready for traffic.

Care and maintenance

Use a pH-neutral cleaner. Avoid abrasive pads and harsh solvents. In high-wear areas, inspect the topcoat periodically; resealing may be needed after several years.

Close out the job

Record the sheen, number of coats and time of the final application so the client knows when the surface can be used. Store remaining unmixed components tightly closed in a cool, dry place.

Product and technical support

INCISE Uganda Limited | info@incise.ug | https://incise.ug/ultra-guard

Satin finish on a decorative corridor floor